Mediul ambiant

Sol si Sedimente

Sol si Sedimente

...

Automated Chemistry Analyzer FS3700

Improve laboratory workflow with the FS3700 by running multiple flow methods (including SFA, FIA, iSFA, and SFIA) on different channels simultaneously. Ideal for the analysis of ammonia, chloride, cyanide, fluoride, nitrate, phenol, phosphorous, silica, TKN, and more! FS3700 Features: Intuitive software - FlowView™ Software streamlines operation Fast results - Performs 30-90 analyses per hour, per channel Versatile – Uses interchangeable, pre-assembled chemistry cartridges Flexible – Tailors methodology with two plug-in detector modules Accurate – Expanded Range™ photometric detector and autoscaling software eliminate off-scale samples Analysis Module 1 or 2 chemical analysis channels per chassis Analysis Module Dimensions 31 in. W x 17.5 in. D x 10.5 in. H 78.74 cm W x 44.45 cm D x 26.67 cm H FS 3700 Dimensions with 90-position Autosampler Approximately 44 in. (112 cm) W FS 3700 Dimensions with 360-position Autosampler Approximately 51.5 in. (131 cm) W Injection Valve 8 or 10-port switching valve with chemically-inert wetted surfaces Photometric Detector 420-880 nm, with PEEK path lengths of 5-, 10- or 20-mm Amperometric Detector Silver working electrode silver/silver chloride reference stainless steel counter electrode In-line Heater Included as needed, mounted underneath chemistry cartridge user programmable in 1 ̊C increments UV-digestion Module Included as needed, mounted underneath chemistry cartridge Peristaltic Pump 24-channel, fits on top of analysis module Autosampler 90-position, X-Y-Z (90 samples + 9 standards) 360-position, X-Y-Z (360 samples + 10 standards) Tubing FEP Teflon® and EVA ethylene-vinyl acetate copolymer Manifolds / Fittings Polysulfone Analysis Methods / Documentation Validated chemistries for specific analytes / sample matrices with performance data Operating Software FlowView Operating System Windows® 7, Windows® 8, 8.1 and 10 Data Collection 6 channels per instance of software Multiple instances of software can be run on a single computer PC to FS 3700 Communications USB Power Supply 24VDC universal switching power supply for operation with 90-250VAC 50/60Hz source Power Requirements 110VAC/60 Hz or 230VAC/50 Hz Weight (Analysis Module) 19.5 kg (43 lbs.), typical for analysis module and pump, two injection valves, chemistry cartridges, detector modules Certifications CE Safety EN 61010-1 EMC Immunity & Emissions EN 61326-1:2006 Methods:  Ammonia Nitrogen by USEPA 350.1 Ammonia/TKN by SFA and Gas Diffusion ASTM D7237 Available Cyanide by ASTM D6888 Chloride by Standard Methods Free Cyanide by ISO 14403 Hexavalent Chromium Low-Level Phosphorus (All Forms) by USEPA 365.1 MBAS by ISO 16265 Nitrate Nitrite in Water using FIA & SFA Nitrate and Nitrite in Milk OIA-1677 Available Cyanide by Ligand Exchange Post-Distillation Cyanide by USEPA 335.4 Post-distillation Phenol by USEPA-420.4 Sulfate by USEPA 375.2    
...

8890 GC System

The browser interface provides remote connectivity enables you to monitor your GC system, check system logs, and perform diagnostics tests, from inside, as well as outside, the laboratory. The full-function touch screen gives a visual report of the system configuration letting you update methods and sequences, perform maintenance routines, and check instrument status. Built-in intelligence autonomously monitors the health of the system, alerts the user of potential issues before they affect chromatographic performance, and offers helpful step-by-step guides to resolve issues. Unique 6th-generation microchannel-based EPC architecture provides a significant improvement in reliability and longevity against gas contaminants such as particulates, water, and oils, extending the life of the instrument consumables. Capillary Flow Technology (CFT) provides unique gas flow connections for multidimension gas chromatography (GC x GC/Deans Switch), comprehensive two-dimension gas chromatography (GC x GC) with flow modulation, and backflush at the beginning, middle, or end of an analytical column that are oven mountable and very low thermal mass. Single filament TCD that doesn’t require a separate reference gas, or manual potentiometer adjustment, yet provides a stable baseline with a minimal amount of signal drift commonly seen with valve switching. Autoranging FID provides the ability to detect and quantitate from percent levels to parts per billion (ppb) in a single injection. Sulfur or nitrogen chemiluminescence detector provides low ppb detection, equimolar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix. Cost-saving advanced electronic pneumatic controllers such as Helium Conservation Module, Hydrogen Sensors, and Alternate Carrier Gas Solutions, dramatically reduce the amount of helium used offering both flexibility and higher levels of safety in your laboratory.