Improve laboratory workflow with the FS3700 by running multiple flow methods (including SFA, FIA, iSFA, and SFIA) on different channels simultaneously. Ideal for the analysis of ammonia, chloride, cyanide, fluoride, nitrate, phenol, phosphorous, silica, TKN, and more!
FS3700 Features:
Intuitive software - FlowView™ Software streamlines operation
Fast results - Performs 30-90 analyses per hour, per channel
Versatile – Uses interchangeable, pre-assembled chemistry cartridges
Flexible – Tailors methodology with two plug-in detector modules
Accurate – Expanded Range™ photometric detector and autoscaling software eliminate off-scale samples
Analysis Module
1 or 2 chemical analysis channels per chassis
Analysis Module Dimensions
31 in. W x 17.5 in. D x 10.5 in. H
78.74 cm W x 44.45 cm D x 26.67 cm H
FS 3700 Dimensions with 90-position Autosampler
Approximately 44 in. (112 cm) W
FS 3700 Dimensions with 360-position Autosampler
Approximately 51.5 in. (131 cm) W
Injection Valve
8 or 10-port switching valve with chemically-inert wetted surfaces
Photometric Detector
420-880 nm, with PEEK path lengths of 5-, 10- or 20-mm
Amperometric Detector
Silver working electrode
silver/silver chloride reference
stainless steel counter electrode
In-line Heater
Included as needed, mounted underneath chemistry cartridge
user programmable in 1 ̊C increments
UV-digestion Module
Included as needed, mounted underneath chemistry cartridge
Peristaltic Pump
24-channel, fits on top of analysis module
Autosampler
90-position, X-Y-Z (90 samples + 9 standards)
360-position, X-Y-Z (360 samples + 10 standards)
Tubing
FEP Teflon® and EVA ethylene-vinyl acetate copolymer
Manifolds / Fittings
Polysulfone
Analysis Methods / Documentation
Validated chemistries for specific analytes / sample matrices with performance data
Operating Software
FlowView
Operating System
Windows® 7, Windows® 8, 8.1 and 10
Data Collection
6 channels per instance of software
Multiple instances of software can be run on a single computer
PC to FS 3700 Communications
USB
Power Supply
24VDC universal switching power supply for operation with 90-250VAC 50/60Hz source
Power Requirements
110VAC/60 Hz or 230VAC/50 Hz
Weight (Analysis Module)
19.5 kg (43 lbs.), typical for analysis module and pump, two injection valves, chemistry cartridges, detector modules
Certifications
CE Safety EN 61010-1
EMC Immunity & Emissions EN 61326-1:2006
Methods:
Ammonia Nitrogen by USEPA 350.1
Ammonia/TKN by SFA and Gas Diffusion
ASTM D7237
Available Cyanide by ASTM D6888
Chloride by Standard Methods
Free Cyanide by ISO 14403
Hexavalent Chromium
Low-Level Phosphorus (All Forms) by USEPA 365.1
MBAS by ISO 16265
Nitrate Nitrite in Water using FIA & SFA
Nitrate and Nitrite in Milk
OIA-1677 Available Cyanide by Ligand Exchange
Post-Distillation Cyanide by USEPA 335.4
Post-distillation Phenol by USEPA-420.4
Sulfate by USEPA 375.2