Analize chimice

Automated Chemistry Analyzers

Automated Chemistry Analyzers

...

Automated Chemistry Analyzer FS3700

Improve laboratory workflow with the FS3700 by running multiple flow methods (including SFA, FIA, iSFA, and SFIA) on different channels simultaneously. Ideal for the analysis of ammonia, chloride, cyanide, fluoride, nitrate, phenol, phosphorous, silica, TKN, and more! FS3700 Features: Intuitive software - FlowView™ Software streamlines operation Fast results - Performs 30-90 analyses per hour, per channel Versatile – Uses interchangeable, pre-assembled chemistry cartridges Flexible – Tailors methodology with two plug-in detector modules Accurate – Expanded Range™ photometric detector and autoscaling software eliminate off-scale samples Analysis Module 1 or 2 chemical analysis channels per chassis Analysis Module Dimensions 31 in. W x 17.5 in. D x 10.5 in. H 78.74 cm W x 44.45 cm D x 26.67 cm H FS 3700 Dimensions with 90-position Autosampler Approximately 44 in. (112 cm) W FS 3700 Dimensions with 360-position Autosampler Approximately 51.5 in. (131 cm) W Injection Valve 8 or 10-port switching valve with chemically-inert wetted surfaces Photometric Detector 420-880 nm, with PEEK path lengths of 5-, 10- or 20-mm Amperometric Detector Silver working electrode silver/silver chloride reference stainless steel counter electrode In-line Heater Included as needed, mounted underneath chemistry cartridge user programmable in 1 ̊C increments UV-digestion Module Included as needed, mounted underneath chemistry cartridge Peristaltic Pump 24-channel, fits on top of analysis module Autosampler 90-position, X-Y-Z (90 samples + 9 standards) 360-position, X-Y-Z (360 samples + 10 standards) Tubing FEP Teflon® and EVA ethylene-vinyl acetate copolymer Manifolds / Fittings Polysulfone Analysis Methods / Documentation Validated chemistries for specific analytes / sample matrices with performance data Operating Software FlowView Operating System Windows® 7, Windows® 8, 8.1 and 10 Data Collection 6 channels per instance of software Multiple instances of software can be run on a single computer PC to FS 3700 Communications USB Power Supply 24VDC universal switching power supply for operation with 90-250VAC 50/60Hz source Power Requirements 110VAC/60 Hz or 230VAC/50 Hz Weight (Analysis Module) 19.5 kg (43 lbs.), typical for analysis module and pump, two injection valves, chemistry cartridges, detector modules Certifications CE Safety EN 61010-1 EMC Immunity & Emissions EN 61326-1:2006 Methods:  Ammonia Nitrogen by USEPA 350.1 Ammonia/TKN by SFA and Gas Diffusion ASTM D7237 Available Cyanide by ASTM D6888 Chloride by Standard Methods Free Cyanide by ISO 14403 Hexavalent Chromium Low-Level Phosphorus (All Forms) by USEPA 365.1 MBAS by ISO 16265 Nitrate Nitrite in Water using FIA & SFA Nitrate and Nitrite in Milk OIA-1677 Available Cyanide by Ligand Exchange Post-Distillation Cyanide by USEPA 335.4 Post-distillation Phenol by USEPA-420.4 Sulfate by USEPA 375.2