Improve laboratory workflow with the FS3700 by running multiple flow methods (including SFA, FIA, iSFA, and SFIA) on different channels simultaneously. Ideal for the analysis of ammonia, chloride, cyanide, fluoride, nitrate, phenol, phosphorous, silica, TKN, and more!
FS3700 Features:
	Intuitive software - FlowView™ Software streamlines operation
	Fast results - Performs 30-90 analyses per hour, per channel
	Versatile – Uses interchangeable, pre-assembled chemistry cartridges
	Flexible – Tailors methodology with two plug-in detector modules
	Accurate – Expanded Range™ photometric detector and autoscaling software eliminate off-scale samples
	
		
			Analysis Module
			1 or 2 chemical analysis channels per chassis
		
		
			Analysis Module Dimensions
			31 in. W x 17.5 in. D x 10.5 in. H
			78.74 cm W x 44.45 cm D x 26.67 cm H
		
		
			FS 3700 Dimensions with 90-position Autosampler
			Approximately 44 in. (112 cm) W
		
		
			FS 3700 Dimensions with 360-position Autosampler
			Approximately 51.5 in. (131 cm) W
		
		
			Injection Valve
			8 or 10-port switching valve with chemically-inert wetted surfaces
		
		
			Photometric Detector
			420-880 nm, with PEEK path lengths of 5-, 10- or 20-mm
		
		
			Amperometric Detector
			Silver working electrode
			silver/silver chloride reference
			stainless steel counter electrode
		
		
			In-line Heater
			Included as needed, mounted underneath chemistry cartridge
			user programmable in 1 ̊C increments
		
		
			UV-digestion Module
			Included as needed, mounted underneath chemistry cartridge
		
		
			Peristaltic Pump
			24-channel, fits on top of analysis module
		
		
			Autosampler
			90-position, X-Y-Z (90 samples + 9 standards)
			360-position, X-Y-Z (360 samples + 10 standards)
		
		
			Tubing
			FEP Teflon® and EVA ethylene-vinyl acetate copolymer
		
		
			Manifolds / Fittings
			Polysulfone
		
		
			Analysis Methods / Documentation
			Validated chemistries for specific analytes / sample matrices with performance data
		
		
			Operating Software
			FlowView
		
		
			Operating System
			Windows® 7, Windows® 8, 8.1 and 10
		
		
			Data Collection
			6 channels per instance of software
			Multiple instances of software can be run on a single computer
		
		
			PC to FS 3700 Communications
			USB
		
		
			Power Supply
			24VDC universal switching power supply for operation with 90-250VAC 50/60Hz source
		
		
			Power Requirements
			110VAC/60 Hz or 230VAC/50 Hz
		
		
			Weight (Analysis Module)
			19.5 kg (43 lbs.), typical for analysis module and pump, two injection valves, chemistry cartridges, detector modules
		
		
			Certifications
			CE Safety EN 61010-1
			EMC Immunity & Emissions EN 61326-1:2006
		
	
Methods: 
Ammonia Nitrogen by USEPA 350.1
Ammonia/TKN by SFA and Gas Diffusion
ASTM D7237
Available Cyanide by ASTM D6888
Chloride by Standard Methods
Free Cyanide by ISO 14403
Hexavalent Chromium
Low-Level Phosphorus (All Forms) by USEPA 365.1
MBAS by ISO 16265
Nitrate Nitrite in Water using FIA & SFA
Nitrate and Nitrite in Milk
OIA-1677 Available Cyanide by Ligand Exchange
Post-Distillation Cyanide by USEPA 335.4
Post-distillation Phenol by USEPA-420.4
Sulfate by USEPA 375.2